TURBIMAX TURBIDITY SENSOR

Turbimax CUS 41 Sensor

Turbidity Sensor

Application Areas

  • Sewage treatment plants
  • Water monitoring
  • Wastewater monitoring
  • Water processing
  • Monitoring tramp oil in coolant
  • Concrete - measurement of soiling
  • Paper - monitoring of sieve water

Your Benefits

  • Measuring range from 0.01 FNU to 300 g/l
  • Scratch-proof sapphire windows
  • Compact shock-proof design
  • For installation in pipes, basins and process tanks
  • Simple commissioning
  • 3-point calibration and 1-point adjustment
  • 7 calibration data records according to customer specifications can be stored
  • Integrated wiper cleaning
  • Inclined flat sensor surface uses medium flow to increase self-cleaning effect
  • Permissible distance between sensor and transmitter of up to 200m/656ft

Technical Specifications

Measuring Principle
Nephelometric 90° NIR scattered light
according to EN 27027
Measuring Range
(with CUS41 sensor)
0.00 to 9999 FNU
0.00 to 9999 ppm
0.0 to 300.0 g/l
0.0 to 200.0%
Wavelength
880nm
Temperature/Pressure
25°C at 6 bar
50°C at 1 bar
Max cable length 200m
Ingress Protection
IP68
Materials Sensor support, shaft, cable: PVC
Optical windows: sapphire



CE


Page reviewed: 12th December 2014